Differences

This shows you the differences between two versions of the page.

Link to this comparison view

public:hardware:headnode:start [2012/04/16 14:21]
jonmills [Network Configuration]
public:hardware:headnode:start [2014/03/20 14:09] (current)
jonmills
Line 1: Line 1:
 ====== ExoGENI Head Node ====== ====== ExoGENI Head Node ======
  
-==== Example Hardware Specs ==== +==== IBM x3650 M4  ==== 
- +^ Part Number ^ Description ^ Quantity ^ 
- +| 7915AC1|IBM System x3650 M4|1| 
- +| A2N2  |ServeRAID M5110e SAS/SATA Controller for IBM System x| 
- +| A1JX  |x3650 M4 8x 2.5" HS HDD Assembly Kit| 
-==== Network Configuration ==== +| A1LF  |IBM System x Lightpath Kit| 
- +| 3757  |IBM Single Cable USB Conversion Option (UCO)| 
-=== Interfaces === +A3V6  |IBM System x3650 M4 Planar (IVB Refresh )| 
- +6263  |4.3m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable
-^ Bond ^ Slave Interfaces ^ VLAN(s^ Tagging ^ Purpose ^ +A1LA  |x3650 M4 System Level Code| 
-bond0 eth0 (from public); eth4 (from Port 47 on BNT8052) | 1010 untagged Public +A1ML  |IBM Integrated Management Module Advanced Upgrade
-bond1 eth1, eth5 1009 untagged iSCSI +A1JZ  |System Documentation and Software-US English| 
-bond2 eth2,eth3,eth6,eth7 1006,1007,1008 tagged Mgt, OpenStack, xCAT +9206  |No Preload Specify
- +| A2R0  |x3650 M4 Mini SAS Cable 820MM| 
-=== A Word on Public Interface Connection === +| A1L8  |x3650 M4 Riser 2 Bracket| 
-In an ideal scenario, the head node has public access failover capability, via a bonded active/active or active/passive interface.  In that scenario, the provider has two cables providing public-facing connectivity.  One runs to the head node, and the other runs to the SSG5.  For example: +| A1JP  |x3650 M4 PCIe Riser Card 1 (1 x16 FH/FL + 1 x8 FH/HL Slots)| 
- +| 5977  |Select Storage devices no IBM-configured RAID required| 
-  * Go to eth0 on head node +| A1KF  |IBM System x3650 M4 2.5" Base without Power Supply| 
-  * Goes to 0/0 on SSG5 +| A1LB  |x3650 M4 Agency Label GBM| 
-    * Go to port 48 on mgt switch (BNT8052+| 8971  |Integrate in manufacturing| 
-    * Go from port 47 on mgt switch back to eth4 on head node +| 2306  |Rack Installation >1U Component| 
- +| 8034  |e1350 Solution Component| 
-The SSG5 has an IPSEC tunnel back to an SSG5 tunnel at RENCI.  If the cable running to eth0 loses network connectivity, then hopefully the head node would still be able to speak to RENCI via the SSG5 link.+| A193  |Integrated Solutions| 
 +| 3101  |Rack 01| 
 +| A2U4  |IBM 128GB SATA 2.5" MLC HS Enterprise Value SSD|2| 
 +| A1H5  |IBM System x 750W High Efficiency Platinum AC Power Supply|2| 
 +| A3VY  |Addl Intel Xeon Processor E5-2640 v2 8C 2.0GHz 20MB Cache 95W| 
 +| 3737  |3m Molex Direct Attach Copper SFP+ Cable| 
 +| A3QE  |4GB (1x4GB, 1Rx4, 1.35V) PC3L-12800 CL11 ECC DDR3 1600MHz LP RDIMM|8| 
 +| 6311  |2.8m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable| 
 +| A3VE  |Intel Xeon Processor E5-2640 v2 8C 2.0GHz 20MB Cache1600MHz 95W| 
 +| A2ZQ  |Mellanox ConnectX-3 EN Dual-port SFP+ 10GbE Adapter|2| 
 +| A1JU  |x3650 M4 PCIe Gen-III Riser Card 2 (1 x8 FH/FL + 2 x8 FH/HL Slots)| 
 +| A2HR  |Configuration ID 03| 
 +| 3222  |Rack location U22| 
 +| 5374CM1|Configuration Instruction| 
 +| A2N2  |ServeRAID M5110e SAS/SATA Controller for IBM System x| 
 +| A2L4  |ServeRAID M5100 Series 1GB Flash/RAID 5 Upgrade Placement| 
 +| A2JX  |Controller 01| 
 +| A2HR  |Configuration ID 03|
Navigation